Products
Direct Electricity meter connection |
||||
Measurement |
active power in 3-phase 4-wire network |
active power in one or two three-phase or four-wire network |
||
One to four tariff. Ability to measure power only in any two phases or in any one phase (when these options must be neutral connected). |
One to four tariff. Ability to measure power in only one phase with the conditions attached neutral. |
|||
Type |
LK13T |
LK13B |
||
Measuring method |
Static meter with current transformers for current input. |
Static meters with shunts for current input. |
||
Class |
A or B |
|||
Display |
LCD |
|||
Reference voltage |
Un |
3x230/400V; 2x230/400V; 230V |
||
Reference frequency |
fn |
50 Hz |
||
Reference current |
Iref |
5A, 10A |
||
Transient current |
Itr |
0,5A |
||
Minimum current |
Imin |
0,15 A; 0,20 A; 0,25 A; 0.5 A |
0,20 A; 0,25 A; 0,5 A |
|
Starting current |
Ist |
15 mA; 20 mA; 25 mA; 50 mA |
20 mA; 25 mA; 50 mA |
|
Maximum current |
Imax |
40 A - 100 A with step 5 A |
||
Constant (LED) |
adjustable from 1000 to 10000 imp/kWh |
|||
Operating temperature |
-40°C till +70°C (LCD is working from -33°C to +60°C) |
|||
Cover |
IP 51 till 54 |
|||
Class of protection (electrical) |
II |
|||
Mechanical environment |
M1 |
|||
Electromagnetic Environment |
E2 |
|||
The meter is connected through a transformer |
||||
Measuring method |
Static meter with current transformers for current input |
|||
Reference current |
Iref /In |
2 A |
5 A |
|
Transient current |
Itr |
0,1 A |
0,25 A |
|
Minimum current |
Imin |
0,02 A |
0.05 A |
|
Starting current |
Ist |
4 mA |
10 mA |
|
Maximum current |
Imax |
6 A |
Direct connection of electricity |
||
Measurement |
active power in 1-phase 2-wire network |
|
One to four tariffs |
||
Type |
LK11B |
|
Measuring method |
Static meters with shunts for current input |
|
Class |
A or B |
|
Display |
LCD |
|
Reference voltage |
Un |
230V |
Reference frequency |
fn |
50 Hz |
Reference current |
Iref |
5 A; 10 A |
Transient current |
Itr |
0,5A |
Minimum current |
Imin |
0,15 A; 0,20 A; 0,25 A; 0.5 A |
Maximum current |
Imax |
40A - 80A with step 5A |
Constant (LED) |
adjustable from 1000 - 10000 imp./kWh |
|
Operating temperature |
-40°C till +70°C |
|
Cover |
IP51 till IP54 |
|
Class of protection (electrical) |
II |
|
Mechanical environment |
M1 |
|
Electromagnetic Environment |
E2 |
Options |
|||
Communication |
S0 |
RS 232 |
RS 485 |
Internal clock |
timestamp register |
for tariff control internal program |
|
Buttons |
internal |
external |
combination |
Relay power management |
AC 230V / 6 A |
||
Disconnector |
In the current range 40 - 100 A |
||
LCD display |
three types |
1; 1,5 and 2 line design |
|
Terminal boards |
two types |
Imax. 80 A a Imax. 120 A |
News
E-world energy & water fair 2020
LOGAREX Smart Metering, s.r.o. exhibits at the E-world energy & water 2020 international fair in Essen.
European Utility Week Fair 2019
LOGAREX Smart Metering, s.r.o., exhibits at the European Utility Week 2019 fair in Paris.
SHOW ALL
Career
Programmer
Requirements:
- University degree - Electrical focus
- Experience required, experience with programming firmware to devices
- The required knowledge of the programming language C++
...
Place of work:
Hradec Králové
Researcher
Requirements:
- Electrical education
- Knowledge of English
- Driving license. B
...
Place of work:
East Bohemia
SHOW ALL